En.06 Unrecoverable Condition-No Blowers Installed; Temperature Conditions; Temperature Sensor Element Numbering - HP StorageWorks 6100 - Enterprise Virtual Array User Manual

Hp storageworks 4x00/6x00/8x00 enterprise virtual array user guide (5697-8037, april 2009)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

0.3.en.06 UNRECOVERABLE condition—No blowers installed
NOTE:
IMPORTANT
When this condition exists there will be two error messages.
The first message will be 0.3.en.05 and will identify the first blower.
The second message will be 0.3.en.06 and will identify the second blower.
The EMU cannot detect any installed blowers. Shutdown is imminent! The EMU will shut down the
enclosure in seven minutes unless you correct the problem. This condition report remains active until
you correct the problem or the EMU shuts down the power supplies, whichever occurs first.
Complete the following procedure to correct this problem.
1.
Record all six characters of the condition report.
2.
Use the controller shutdown procedure to shut down the controllers.
3.
Contact your authorized service representative.
CAUTION:
An automatic shutdown and possible data corruption may result if the
replacement is available.

Temperature conditions

The format of a temperature condition report is 0.4.en.ec, where:
0.4. is the temperature sensor element type
en. is the two-character temperature sensor element
ec is the error code
See
Table 42
Table 42 Temperature sensor element numbering
Sensor
01.
02.
03.
04.
05.
06.
07.
152
EMU-generated condition reports
to determine the location of each temperature sensor.
Sensor location
Power Supply 1 Exhaust
Power Supply 2 Exhaust
EMU
Drive Bay 1
Drive Bay 2
Drive Bay 3
Drive Bay 4
blower
Sensor
10.
Drive Bay 7
11.
Drive Bay 8
12.
Drive Bay 9
13.
Drive Bay 10
14.
Drive Bay 11
15.
Drive Bay 12
16.
Drive Bay 13
is removed before a
Sensor location

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks 6100 - Enterprise Virtual Array and is the answer not in the manual?

Questions and answers

Table of Contents