Figure 47 Installing a power supply
Verifying proper operation
After replacing the power supply, check the following to verify that the component is operating
properly:
•
Check the power supply status indicator. It should be green.
•
Navigate back to the component and check the status. It should be
Turn off the locate function by clicking Locate > Locate Off .
•
Returning the failed component
Follow the return instructions provided with the new component.
Replacing a disk drive
This section describes the procedure for replacing a Fibre Channel disk drive.
Before you begin
Observe the following precautions when replacing the disk drive.
CAUTION:
Ensure you have a replacement part available before removing the failed component. Removing a
component impacts cooling within the enclosure.
•
Do not remove more than one disk drive at a time from the enclosure. Doing so will impact cooling
of the enclosure and may cause data loss.
•
Parts can be damaged by electrostatic discharge. Use proper anti-static protection. See the docu-
mentation that shipped with your system for additional information.
•
Have a copy of the product User Guide available for reference. You can download a copy of the
User Guide from the product support page on the HP website.