Figure 47 Installing a power supply

Verifying proper operation

After replacing the power supply, check the following to verify that the component is operating
properly:
Check the power supply status indicator. It should be green.
Navigate back to the component and check the status. It should be
Turn off the locate function by clicking Locate > Locate Off .

Returning the failed component

Follow the return instructions provided with the new component.

Replacing a disk drive

This section describes the procedure for replacing a Fibre Channel disk drive.

Before you begin

Observe the following precautions when replacing the disk drive.
CAUTION:
Ensure you have a replacement part available before removing the failed component. Removing a
component impacts cooling within the enclosure.
Do not remove more than one disk drive at a time from the enclosure. Doing so will impact cooling
of the enclosure and may cause data loss.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection. See the docu-
mentation that shipped with your system for additional information.
Have a copy of the product User Guide available for reference. You can download a copy of the
User Guide from the product support page on the HP website.

Types of disk failures

There are two types of disk failures:
114
Customer replaceable units
1
2
0138a
.