2
1
Figure 8 Removing the drive blank
1. Upper mounting tab

Changing the Device Addition Policy

To prevent the storage system from automatically grouping a new disk drive that may have the incorrect
firmware on it, the Device Addition Policy must be checked and set to manual if necessary:
1.
Open HP Command View EVA and in the Navigation pane select th storage system.
The Initialized Storage System Properties window opens.
2.
Click System Options.
3.
Select Set system operational policies.
4.
If the Device Addition Policy is set to Automatic, change it to Manual.
5.
Click Save changes.
NOTE:
If you want to return the Device Addition Policy to automatic, repeat steps 1 through 5 after verifying
the disk drive has the correct firmware version.

Installing the disk drive

1.
Push in the ejector button on the disk drive and pull the release lever down to the full open position.
2.
Insert the drive into the enclosure as far as it will go (1,
3.
Close the release lever until it engages the ejector button, and the disk drive seats in the backplane
(2,
Figure
4.
Press in firmly on the disk drive to ensure it is seated properly.
48
Enterprise Virtual Array operation
CXO7359B ˚
9).
2. Lower mounting tab
Figure
9).