En.03 Information Condition-Drive Software Lock Active; En.04 Critical Condition-Loop A Drive Link Rate Incorrect; En.05 Critical Condition-Loop B Drive Link Rate Incorrect - HP StorageWorks 6100 - Enterprise Virtual Array User Manual

Hp storageworks 4x00/6x00/8x00 enterprise virtual array user guide (5697-8037, april 2009)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

1.
Record all six characters of the condition report.
2.
Remove and install the drive to ensure that it is properly installed.
3.
Observe the EMU to ensure the error is corrected.
4.
If removing and installing the drive did not correct the problem, install a replacement drive or a
drive blank.
5.
Observe the EMU to ensure the error is corrected.
6.
If unable to correct the problem, contact your authorized service representative.
0.1.en.03 INFORMATION condition—Drive software lock active
Some enclosures have a software-activated lock that prevents physically removing a drive while this
feature is active. This feature can be activated even when an enclosure does not have a physical lock.
Removing a drive when this feature is active generates a condition report. This error remains active
for 15 seconds.
No action is required to correct this condition.
0.1.en.04 CRITICAL condition—Loop a drive link rate incorrect
The drive is capable of operating at the loop link rate but is running at a different rate. For example,
the drive is operating at 1 Gbps, and the loop is operating at 2 Gbps. Only when the drive is operating
at the Fibre Channel link rate established by the I/O module can this drive transfer data.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Remove and replace the drive in the enclosure.
3.
Observe the drive status indicators to ensure the drive is operational.
4.
Observe the EMU to ensure the error is corrected.
5.
If removing and replacing the drive did not correct the problem, replace the drive.
6.
Observe the drive status indicators to ensure the drive is operational.
7.
Observe the EMU to ensure the error is corrected.
8.
If unable to correct the problem, contact your authorized service representative.
0.1.en.05 CRITICAL condition—Loop b drive link rate incorrect
The drive is capable of operating at the loop link rate but is running at a different rate. For example,
the drive is operating at 1 Gbps, and the loop is operating at 2 Gbps. Only when the drive is operating
at the Fibre Channel link rate established by the I/O module can this drive transfer data.
This error remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Remove and replace the drive in the enclosure.
3.
Observe the drive status indicators to ensure the drive is operational.
4.
Observe the EMU to ensure the error is corrected.
148
EMU-generated condition reports