Sun Solaris Configuration; Requirements; Hba Configuration; Risks - HP StorageWorks 6100 - Enterprise Virtual Array User Manual

Hp storageworks 4x00/6x00/8x00 enterprise virtual array user guide (5697-8037, april 2009)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

2 Management server
3 Host 1
4 Host 2
5 Host 3

SUN Solaris configuration

Requirements

Switch zoning or controller level SSP must be used to ensure each single path HBA has an exclusive
path to its LUNs.
Single path HBA server can be in the same fabric as servers with multiple HBAs.
Single path HBA server cannot share LUNs with any other HBAs.
In the use of snapshots and snapclones, the source virtual disk and all associated snapshots and
snapclones must be presented to the single path hosts that are zoned with the same controller. In
the case of snapclones, after the cloning process has completed and the clone becomes an ordinary
virtual disk, you may present that virtual disk as you would any other ordinary virtual disk.
HBA must be properly configured to work in a single HBA server configuration. The user is required
to:
• Download and extract the contents of the TAR file.

HBA configuration

Host 1 is a single path HBA host.
Host 2 is a multiple HBA host with multi-pathing software.
See
Figure
78.

Risks

Single path failure may result in loss of data accessibility and loss of host data that has not been
written to storage.
Controller shutdown results in loss of data accessibility and loss of host data that has not been
written to storage.
NOTE:
For additional risks, see

Limitations

HP Continuous Access EVA is not supported with single path configurations.
Single path HBA server is not part of a cluster.
Booting from the SAN is not supported.
190
Single Path Implementation
Table 58
on page 203.
7 SAN switch 2
8 Controller A
9 Controller B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents