Figure 56 Checking model number and firmware version

Adding the disk to a disk group

After replacing the disk, it should be added to a disk group. The disk is typically added back into its
original disk group.
1.
In the Navigation pane, select Storage system > Hardware > Rack > Disk enclosure > Bay.
2.
In the Content pane, select the Disk Drive tab.
3.
Click Group to initiate the process for adding the disk to a disk group.
Operation Successful displays, indicating the disk is now grouped, leveling has been initiated,
and the storage system begins immediately using the disk.
NOTE:
If the Device Addition Policy is set to automatic, the disk will automatically be added to a disk group.
In this case the Group option will not be available.

Returning the failed component

Follow the return instructions provided with the new component.

Replacing the disk enclosure power supply/blower

This section describes the procedure for replacing the power supply/blower assembly.
NOTE:
Because this component is used in several products, the drawings may reflect a different enclosure
than the one you have. The removal and replacement procedure is the same for each product.

Before you begin

Observe the following precautions when replacing the power supply/blower.