Unrecoverable Condition-Emu Hardware Failure; Information Condition-Emu Internal Esi Data Corrupted; Unrecoverable Condition-Power Shutdown Failure - HP StorageWorks 6100 - Enterprise Virtual Array User Manual

Hp storageworks 4x00/6x00/8x00 enterprise virtual array user guide (5697-8037, april 2009)
Hide thumbs Also See for StorageWorks 6100 - Enterprise Virtual Array:
Table of Contents

Advertisement

address bus enclosure ID expansion cable. This condition report remains active until the problem is
corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Remove and reconnect the cable between the address bus enclosure ID expansion cable and the
EMU.
NOTE:
The EMU display may not display a change in condition for up to 30 seconds.
3.
Observe the EMU to ensure the error is corrected.
4.
If the problem is not corrected, remove and reinstall the lower and upper terminators, and all the
enclosure ID expansion cable-to-enclosure ID expansion cables.
5.
Observe the EMU to ensure the error is corrected.
6.
Reset the EMU, then observe the EMU to ensure the error is corrected.
7.
If resetting the EMU did not correct the problem, contact your HP authorized service representative.
0.7.01.15 UNRECOVERABLE condition—EMU hardware failure
The EMU has detected an internal hardware problem. This condition report remains active until the
problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Reset the EMU.
3.
Observe the EMU to ensure the error does not recur within the first minute.
4.
If the error does recur, contact your HP authorized service representative. The EMU is inoperative
and must be replaced as soon as possible.
0.7.01.16 INFORMATION condition—EMU internal ESI data corrupted
The EMU ESI data is corrupted. This condition does not affect any other element and no action is
required.
0.7.01.17 UNRECOVERABLE condition—Power shutdown failure
The power supply did not respond to a controller, EMU, or power supply shut down command. Shutting
down the supply is required to prevent overheating.
Complete the following procedure to correct the problem:
1.
Record all six characters of the condition report.
2.
Move the power cord
158
EMU-generated condition reports
bail lock
1,
Figure
67, to the left.