Noncritical Condition-Emu Cannot Read Nvram Data; Unrecoverable Condition-Emu Load Failure; Noncritical Condition-Emu Enclosure Address; Unrecoverable Condition-Emu Hardware Failure - HP 6100 User Manual

Enterprise virtual array
Hide thumbs Also See for 6100:
Table of Contents

Advertisement

0.7.01.12 NONCRITICAL condition—EMU cannot read NVRAM data
The EMU is unable to read data from the NVRAM. This condition report remains active until the
problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Reset the EMU.
3.
Observe the EMU to ensure the error is corrected.
4.
If resetting the enclosure did not correct the problem, contact your HP authorized service
representative.
0.7.01.13 UNRECOVERABLE condition—EMU load failure
The EMU Field Programmable Gate Array (FPGA) that controls the ESI bus failed to load information
required for EMU operation. This condition report remains active until the problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Reset the EMU.
3.
Observe the EMU to ensure the error is corrected.
4.
If resetting the enclosure did not correct the problem, contact your HP authorized service
representative.
0.7.01.14 NONCRITICAL condition—EMU enclosure address
Either the enclosure address is incorrect or the enclosure has no address. Possible causes include
a defective enclosure address bus cable, an incorrectly connected cable, or a defective enclosure
address bus enclosure ID expansion cable. This condition report remains active until the problem
is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Remove and reconnect the cable between the address bus enclosure ID expansion cable and
the EMU.
NOTE:
3.
Observe the EMU to ensure the error is corrected.
4.
If the problem is not corrected, remove and reinstall the lower and upper terminators, and all
the enclosure ID expansion cable-to-enclosure ID expansion cables.
5.
Observe the EMU to ensure the error is corrected.
6.
Reset the EMU, then observe the EMU to ensure the error is corrected.
7.
If resetting the EMU did not correct the problem, contact your HP authorized service
representative.
0.7.01.15 UNRECOVERABLE condition—EMU hardware failure
The EMU has detected an internal hardware problem. This condition report remains active until
the problem is corrected.
Complete the following procedure to correct this problem:
1.
Record all six characters of the condition report.
2.
Reset the EMU.
3.
Observe the EMU to ensure the error does not recur within the first minute.
4.
If the error does recur, contact your HP authorized service representative. The EMU is
inoperative and must be replaced as soon as possible.
132 EMU-generated condition reports
The EMU display may not display a change in condition for up to 30 seconds.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eva4000Eva6000Eva8000Eva4100Eva6100Eva8100

Table of Contents