Chapter 23
Configuring Inter-VSAN Routing
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Step 2
Verify that IVR is enabled on every IVR-enabled switch.
switch# show ivr
Inter-VSAN Routing is enabled
Inter-VSAN enabled switches
---------------------------
No IVR-enabled VSAN is active. Check VSAN-Topology configuration.
Inter-VSAN topology status
--------------------------
Current Status: Inter-VSAN topology is INACTIVE
Inter-VSAN zoneset status
-------------------------
Fabric distribution status
-----------------------
fabric distribution disabled
Last Action
Last Action Result
Last Action Failure Reason : None
Inter-VSAN NAT mode status
--------------------------
FCID-NAT is disabled
License status
-----------------
IVR is running based on the following license(s)
ENTERPRISE_PKG
Enable CFS distribution on every IVR-enabled switch in the fabric.
Step 3
switch# config t
Enter configuration commands, one per line.
switch(config)# ivr distribution
Enable IVR auto-topology mode.
Step 4
switch(config)# ivr vsan-topology auto
fabric is locked for configuration. Please commit after configuration is done.
Step 5
Commit the change to the fabric.
switch(config)# ivr commit
switch(config)# exit
switch#
Verify the status of the commit request.
Step 6
switch# show ivr session status
Last Action
Last Action Result
Last Action Failure Reason : None
Verify the active IVR topology.
Step 7
switch# show ivr vsan-topology active
AFID
OL-18084-01, Cisco MDS NX-OS Release 4.x
name
:
state
: idle
last activate time :
SWITCH WWN
: None
: None
End with CNTL/Z.
: Commit
: Success
Active
Cfg. VSANS
Cisco MDS 9000 Family CLI Configuration Guide
Example Configurations
23-43
Need help?
Do you have a question about the AP776A - Nexus Converged Network Switch 5020 and is the answer not in the manual?
Questions and answers