Cisco AP776A - Nexus Converged Network Switch 5020 Configuration Manual page 498

Cisco mds 9000 family cli configuration guide - release 4.x (ol-18084-01, february 2009)
Hide thumbs Also See for AP776A - Nexus Converged Network Switch 5020:
Table of Contents

Advertisement

FC IDs
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
INTERFACE
------------------------------------------------------------------------------------------
fc1/9
fc1/10
Note
Step 2
Shut down the HBA interface in the MDS switch.
switch# conf t
switch(config)# interface fc1/9
switch(config-if)# shutdown
switch(config-if)# end
switch#
Verify that the FC ID feature is enabled using the show fcdomain vsan command.
Step 3
switch# show fcdomain vsan 1
...
Local switch configuration information:
If this feature is disabled, continue with this procedure to enable the persistent FC ID.
If this feature is already enabled, skip to
Enable the persistent FC ID feature in the Cisco MDS switch.
Step 4
switch# conf t
switch(config)# fcdomain fcid persistent vsan 1
switch(config)# end
switch#
Assign a new FC ID with a different area allocation. In this example, we replace 77 with ee.
Step 5
switch# conf t
switch(config)# fcdomain fcid database
switch(config-fcid-db)# vsan 3 wwn 50:05:08:b2:00:71:c8:c2 fcid 0x6fee00 area
Step 6
Enable the HBA interface in the Cisco MDS switch.
switch# conf t
switch(config)# interface fc1/9
switch(config-if)# no shutdown
switch(config-if)# end
switch#
Verify the pWWN ID of the HBA using the show flogi database command.
Step 7
switch# show flogi database
------------------------------------------------------------------------------------------
INTERFACE
------------------------------------------------------------------------------------------
fc1/9
fc1/10
Note
Cisco MDS 9000 Family CLI Configuration Guide
18-18
VSAN
FCID
3
0x6f7703
3
0x6f7704
Both FC IDs in this setup have the same area 77 assignment.
State: Enabled
FCID persistence: Disabled
VSAN
FCID
3
0x6fee00
3
0x6f7704
Both FC IDs now have different area assignments.
PORT NAME
50:05:08:b2:00:71:c8:c2
50:06:0e:80:03:29:61:0f
Step
5.
PORT NAME
50:05:08:b2:00:71:c8:c2
50:06:0e:80:03:29:61:0f
Chapter 18
Configuring Domain Parameters
NODE NAME
50:05:08:b2:00:71:c8:c0
50:06:0e:80:03:29:61:0f
NODE NAME
50:05:08:b2:00:71:c8:c0
50:06:0e:80:03:29:61:0f
OL-18084-01, Cisco MDS NX-OS Release 4.x

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents