Chapter 22 Creating Dynamic Vsan; About Dpvm Configuration; Enabling Dpvm - Cisco AP776A - Nexus Converged Network Switch 5020 Configuration Manual

Cisco mds 9000 family cli configuration guide - release 4.x (ol-18084-01, february 2009)
Hide thumbs Also See for AP776A - Nexus Converged Network Switch 5020:
Table of Contents

Advertisement

DPVM
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
DPVM does not cause any changes to device addressing. DPVM only pertains to the VSAN membership
Note
of the device, ensuring that the host gets same VSAN membership on any port on the switch. For
example, if a port on the switch has a hardware failure, you can move the host connection to another port
on the switch and not need to update the VSAN membership manually.
DPVM is not supported on FL ports. DPVM is supported only on F ports.
Note
This section describes DPVM and includes the following topics:

About DPVM Configuration

To use the DPVM feature as designed, be sure to verify the following requirements:
The DPVM feature overrides any existing static port VSAN membership configuration. If the VSAN
Note
corresponding to the dynamic port is deleted or suspended, the port is shut down.

Enabling DPVM

To begin configuring DPVM, you must explicitly enable DPVM on the required switches in the fabric.
By default, this feature is disabled in all switches in the Cisco MDS 9000 Family.
The configuration and verification commands for DPVM are only available when DPVM is enabled on
a switch. When you disable this feature, all related configurations are automatically discarded.
Cisco MDS 9000 Family CLI Configuration Guide
22-2
About DPVM Configuration, page 22-2
Enabling DPVM, page 22-2
About DPVM Databases, page 22-3
Configuring DPVM Config and Pending Databases, page 22-3
Activating DPVM Config Databases, page 22-4
About Autolearned Entries, page 22-4
Enabling Autolearning, page 22-5
Clearing Learned Entries, page 22-5
The interface through which the dynamic device connects to the Cisco MDS 9000 Family switch
must be configured as an F port.
The static port VSAN of the F port should be valid (not isolated, not suspended, and in existence).
The dynamic VSAN configured for the device in the DPVM database should be valid (not isolated,
not suspended, and in existence).
Chapter 22
Creating Dynamic VSANs
OL-18084-01, Cisco MDS NX-OS Release 4.x

Hide quick links:

Advertisement

Table of Contents
loading