Portcfgeport - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual

Brocade fabric os command reference guide v6.1.0 (53-1000599-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

2

portCfgEPort

portCfgEPort
Enables or disables E_Port capability on a port.
Synopsis
portcfgeport [slot/]port,mode
Description
Use this command to enable or disable E_Port capability on a port. E_Port capability is enabled by
default. When an inter-switch link (ISL) is connected to a port and the port's E_Port capability is
disabled, the ISL is segmented. No data traffic between two switches is routed through this port.
Fabric management data, such as zoning information, are not exchanged through this port either.
Regardless of how many E_Ports are connected between two switches, the maximum routing paths
are limited to 16 E_Ports.
Notes
Changes made by this command are persistent across switch reboots or power cycles.
The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands
This command has the following operands:
slot
port
mode
Examples
To disable E_Port capability on a port:
To enable E_Port capability on a port:
See Also
portShow, switchShow
444
For bladed systems only, specify the slot number of the port to be configured,
followed by a slash (/).
Specify the number of the port to be configured, relative to its slot for bladed
systems. Use switchShow to display a list of valid ports.
Specify 1 to enable the port as an E_Port. This is the default port state.
Specify 0 to disable E_Port capability. Mode must be preceded by a comma.
switch:admin> portcfgeport 1/3, 0
switch:admin> portcfgeport 1/3, 1
Fabric OS Command Reference