cfgEnable

Enables a zone configuration.
Synopsis
cfgenable "cfgName"
Description
Use this command to enable a zone configuration. The command builds the specified zone
configuration by checking for undefined zone names, zone alias names, or other inconsistencies,
by expanding zone aliases, removing duplicate entries, and then installing the effective
configuration.
If the build fails, the previous state is preserved (zoning remains disabled, or the previous effective
configuration remains in effect). If the build succeeds, the new configuration replaces the previous
configuration. Refer to the cfgShow command for a description of defined and effective
configurations.
Note
When FCS policy is enabled, this command can be issued only from the primary FCS switch.
Operands
The following operand is required:
"cfgName"
Examples
To enable the zone configuration "USA_cfg":
See Also
cfgClear, cfgDisable, cfgSave, cfgShow
Fabric OS Command Reference
53-1000599-02
Specifies the name of the zone configuration. The name must be enclosed in
quotation marks.
switch:admin> cfgenable "USA_cfg"
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
Do you want to enable 'USA_cfg' configuration
zone config "USA_cfg" is in effect
Updating flash ...
cfgEnable
(yes, y, no, n): [no] y