diagEnablePost

diagEnablePost
Enables power-on self-test (POST) execution at next reboot.
Synopsis
diagenablepost
Description
Use this command to enable POST. A reboot is not required for this command to take effect. POST
includes two phases: POST Phase I mainly tests hardware and POST Phase II tests system
functionality.
Note
The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands
none
Examples
To enable the POST during future power ons:
See Also
diagDisablePost
104
switch:admin> diagenablepost
Config update Succeeded
Diagnostic POST is now enabled.