Ficoncupshow - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual

Brocade fabric os command reference guide v6.1.0 (53-1000599-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

2

ficonCupShow

ficonCupShow
Displays FICON-CUP parameters for a switch.
Synopsis
ficoncupshow fmsmode
ficoncupshow modereg [bitname]
ficoncupshow MIHPTO
Description
Use this command to display FICON-CUP (Control Unit Port) parameters for a switch.
Note
The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details
Operands
This command has the following operands:
fmsmode
modereg
MIHPTO
Examples
To display the FMS mode for the switch:
To display the mode register for the switch:
194
Display the FICON Management Server (FMS) mode for the switch.
Display the FICON-CUP mode register. If no operand is specified, all mode
register bit settings are displayed. If a mode register bit name is specified,
then only the value of that bit is displayed. A value of 1 indicates that a given
mode register bit is set, and 0 indicates that it is not set.
The following operand is optional:
bitname
Displays the specified mode register bit as either set (1) or not set (0). Valid
values for bitname are:
POSC
Programmed offline state control
UAM
User alert mode
ASM
Active=saved mode
DCAM
Director clock alert mode
ACP
Alternate control prohibited
HCP
Host control prohibited
Displays the FICON-CUP missing interrupt handler primary timeout (MIHPTO)
value in seconds.
switch:user> ficoncupshow fmsmode
fmsmode for the switch: Enabled
switch:user> ficoncupshow modereg
POSC
UAM
ASM
DCAM
------------------------------
1
0
1
1
ACP
HCP
1
0