fipsCfg

Configures FIPS (Federal Information Processing Standards) mode.
Synopsis
fipscfg --enable [fips | selftests]
fipscfg --disable [fips | selftests]
fipscfg --zeroize
fipscfg --show | --showall
fipscfg --force fips
fipscfg --verify fips
fipscfg --disable | --enable bootprom
Description
Use this command to configure FIPS mode in the switch. In this mode, only FIPS-compliant
algorithms are allowed. As part of FIPS 140-2 level 2 compliance, passwords, shared secrets and
the private keys used in SSL/TLS, system login, etc., need to be zeroized. Power-up self tests are
executed when the switch is powered on to check for the consistency of the algorithms
implemented in the switch.
Notes
Certain services and functions, such as FTP, HTTP, remote procedure calls (RPC), root account,
boot prom access, etc., must be blocked for the system to enter FIPS mode.
LDAP should not be configured while FIPS is enabled.
The system must be rebooted for FIPS mode changes to take effect.
Refer to the Fabric OS Administrator's Guide for information on configuring your system for FIPS
140-2 level 2 compliance.
FIPS mode cannot be modified through configDownload.
FIPS is not supported on all platforms. For FIPS-compliant hardware, refer to the Fabric OS
Administrator's Guide.
The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands
This command has the following operands:
--disable [fips | selftests]
--enable [fips | selftests]
--zeroize
--show |--showall
Fabric OS Command Reference
53-1000599-02
Disables FIPS or Selftests mode. Note: Selftests cannot be disabled when
FIPS mode is enabled.
Enables FIPS or Selftests mode. Notes: Selftests must be enabled before
FIPS mode is enabled.
Erases all passwords, shared secrets, private keys, etc. in the system.
Displays the current FIPS configuration.
2
fipsCfg
203