portCfgEPort

Enables or disables a port from becoming an E_Port.
Synopsis
portcfgeport [slotnumber/]portnumber, mode
Description
Use this command to enable or disable a port from becoming an E_Port. The E_Port capability is
enabled by default unless this command is used to disable it. When a port is configured as a
non-E_Port through this command, an ISL connected to this port is segmented. No data traffic
between two switches is routed through this port. Fabric management data, such as zoning
information, are not exchanged through this port either.
Regardless of how many E_Ports are connected between two switches, the maximum routing paths
are currently limited to 16 E_Ports.
Notes
Changes made by this command are persistent across switch reboots or power cycles.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands
This command has the following operands:
slotnumber
portnumber
mode
Examples
To disable a port from becoming an E_Port:
To enable a port to become an E_Port:
See Also
portShow, switchShow
Fabric OS Command Reference
53-1000599-01
For bladed systems only, specifies the slot number of the port to be
configured,followed by a slash (/).
Specifies the number of the port to be configured, relative to its slot for
bladed systems. Use switchShow to display a list of valid ports.
Specify 1 to enable the port to become an E_Port. This is the default port
state. Specify 0 to disable the port from becoming an E_Port.
switch:admin> portcfgeport 1/3, 0
switch:admin> portcfgeport 1/3, 1
2