Hashow - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual

Brocade fabric os command reference guide v6.1.0 (53-1000599-02, june 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

haShow

Displays control processor (CP) status.
Synopsis
hashow
Description
Use this command to display control processor status. The display includes:
Note
This command may not be supported on non-bladed systems.
Operands
none
Examples
To display CP status, first on a healthy standby CP and then on a faulty standby CP:
Fabric OS Command Reference
53-1000599-02
Local CP state (slot number and CP ID), warm or cold, recovering or recovered
Remote CP state (slot number and CP ID)
High Availability (enabled or disabled)
Heartbeat (up or down)
Health of standby CP defined as follows:
Healthy
The standby CP is running and the background health diagnostic has not
detected any errors.
Failed
The standby CP is running, but the background health diagnostic has
discovered a problem with the blade. The logs should be checked to
determine the appropriate repair action. Failover is disabled until the standby
CP is repaired. Information about the failing device in the standby CP is
displayed.
Unknown
The standby CP health state is unknown because the standby CP does not
exist, heartbeat is down, or Health Monitor detects a configuration file error.
HA synchronization status:
"HA State synchronized"
The system is currently fully synchronized. If a failover became necessary, it
would be nondisruptive
HA State "not in sync"
The system is unable to synchronize the two CPs. This may be caused by one
or more of the following conditions:
A haFailover was issued. In this case the "HA State 'not in sync'" state is
transitory.
The standby CP is faulty.
A haSyncStop command was issued.
A system error occurred.
If a failover becomes necessary while the CPs are not in sync, the standby CP
reboots, and the failover is disruptive.
switch:admin> hashow
Local CP (Slot 6, CP1): Active, Cold Recovered
Remote CP (Slot 5, CP0): Non-Redundant