fwConfigure

Displays and modifies the Fabric Watch configuration.
Synopsis
fwconfigure
fwconfigure --enable --port portNumber
fwconfigure --disable --port portNumber
Description
Use this command to display and modify threshold information for the Fabric Watch configuration.
Switch elements monitored by Fabric Watch are divided into classes, which are further divided into
areas. Each area can include multiple thresholds. In addition, the command can be used to disable
or enable all thresholds associated with a given port. When executed without operands, this
command runs interactively.
On switches running Fabric OS v 6.1.0 or later, use this command to enable Port Fencing. This
feature allows the OS to disable a port that is operating outside the bounds of normal operation.
When an erratically behaving port is fenced, the port is placed into the disabled state and is kept
offline, thereby preventing the port to transmit or receive frames. Refer to the Fabric Watch
Administrator's Guide for information on how to enable Port Fencing.
The Fabric Watch classes and areas are provided in
1. The Port class does not support VE _Ports and VEX_Ports, except for State Changes.
2. The E_Port class has the same port limitations as the port class except under the following
3. SFP Class: SFPs connected to GbE ports are not monitored. For more Information, refer to the
TABLE 12
Class
Environment
SFP
Port
Fabric OS Command Reference
53-1000599-02
condition: On a Brocade 48000 with a FR4-18i blade, or on the Brocade 7500, the E_Port
class monitors the following additional ports and creates monitors for each of the logical ports:
-
FCR (includes EX_Ports)
-
FCIP (includes VE_Ports, VEX_Ports)
Fabric Watch Administrator's Guide.
fwConfigure Fabric Watch classes and areas
Table
12. The following restrictions apply:
Area
Temperature
Fan*
Power Supply*
Temperature
RXP
TXP
Current
Voltage
Link loss
Sync loss
Signal loss
Protocol error
Invalid words
Invalid CRCS
RX Performance
TX Performance
State Changes
2