Portcamshow - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual

Brocade fabric os command reference manual v6.2.0 (53-1001186-01, april 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

2

portCamShow

portCamShow
Displays port-based filter CAM utilization.
Synopsis
portcamshow [slotnumber/]portnumber
Description
Use this command to display the current filter Content-Addressable Memory (CAM) utilization of a
specified port.
The command displays the following information:
SID used
DID used
SID entries
DID entries
SID free
DID free
Notes
This command cannot be executed on a logical port.
Ports that support shared areas are divided into two ports: primary and secondary ports. Primary
and secondary ports share the same area. Port CAM entries displayed on the primary ports also
consist of all the secondary port SIDs and DIDs as well, when both the ports are F_Ports. This is
because the primary port acts as a proxy for the CAM entries of the secondary port, in this case
using redirect filters.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command
Availability" for details.
Operands
This command has the following operands:
slotnumber
portnumber
536
Total number of CAM entries used by this port. Note that each CAM entry,
either source ID (SID) or destination ID (DID) CAM, can be shared among a
certain number of ports, depending on the ASIC.
Total number of CAM entries used by this port. Note that each CAM entry
(either SID or DID CAM) can be shared among a certain number of ports,
depending on the ASIC.
All existing source ID entries within the CAM for this port. Note that each CAM
entry (either SID or DID CAM) can be shared among a certain number of
ports, depending on the ASIC.
All existing destination ID entries within the CAM for this port. Note that each
CAM entry (either SID or DID CAM) can be among a certain number of ports,
depending on the ASIC.
The total number of free SID CAM entries available for use by this port.
The total number of free DID CAM entries available for use by this port.
For bladed systems only, specifies the slot number of the port to display,
followed by a slash (/).
Specifies the port number to display, relative to its slot for bladed systems.
Use switchShow to list valid ports. This operand is required.
Fabric OS Command Reference
53-1001186-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents