Fwfrucfg - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual

Brocade fabric os command reference manual v6.2.0 (53-1001186-01, april 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

2

fwFruCfg

fwFruCfg
Displays or modifies FRU state alert configuration.
Synopsis
fwfrucfg [--show]
Description
Use this command to configure field-replaceable unit (FRU) states and actions. Based on these
configuration settings, Fabric Watch generates action when a FRU state changes. To configure
email alerts, use fwMailCfg.
Notes
This command requires a Fabric Watch license.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
The command is not applicable to platforms without FRUs.
Operands
This command has the following operand:
--show
If no operand is specified, the configuration prompt displays.
Examples
To change FRU state alert configuration:
See Also
fwConfigure, fwMailCfg
308
Displays the current FRU configuration setting.
switch:admin> fwfrucfg
The current FRU configuration:
Alarm State
-----------------------------------------------
Slot
Power Supply
Fan
WWN
Note that the value 0 for a parameter means that
it is NOT used in the calculation
Configurable Alarm States are:
Absent-1, Inserted-2, On-4, Off-8, Faulty-16
Configurable Alarm Actions are:
Errlog-1, E-mail-16
Slot Alarm State: (0..31) [0] 3
Slot Alarm Action: (0..17) [1]
Power Supply Alarm State: (0..31) [0]
Power Supply Alarm Action: (0..17) [0]
Fan Alarm State: (0..31) [0]
Fan Alarm Action: (0..17) [0]
WWN Alarm State: (0..31) [0]
WWN Alarm Action: (0..17) [0]
Fru configuration successfully changed
Alarm Action
0
1
0
0
0
0
0
0
Fabric OS Command Reference
53-1001186-01