Passwd - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Command Reference Manual

Brocade fabric os command reference manual v6.2.0 (53-1001186-01, april 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

passwd

Changes the password for a specified user.
Synopsis
passwd ["user account"]
Description
Use this command to change a user account password.
Operands
When this command is invoked without operand, the password is changed for the current user
account. The following operand is optional:
"user account"
Passwords can be changed locally on any switch. For the password database to be distributed to
other switches in the fabric, the switches must be configured to accept the password database
with the fddCfg command. The password database is distributed manually with the distribute
command.
If RADIUS authentication is enabled, password change is blocked for users changing their own
password. Administrators with the privilege to change passwords for other accounts may do so
regardless of whether RADIUS authentication is enabled; all such password changes operate on
the local password database.
The passwd command cannot be run on the Standby CP. When an admin account or a
SecurityAdmin account changes the password for other accounts, it does not prompt for the current
password, unless the target account is a factory or root account.
Any chosen password must satisfy the following password strength rules:
The password history policy is enforced across all user accounts when the user is setting his own
password. The password history policy is not enforced when an administrator sets a password for
another user, but the user's password history is preserved and the password set by the
administrator is recorded in the user's password history.
The passwd command behaves as follows:
Fabric OS Command Reference
53-1001186-01
Specifies the user account for which the password is to be changed. The user
account must be enclosed in double quotation marks, The user account must
be an existing account, either default or user-created. Only users with
accounts of type "root", "factory", "SecurityAdmin", or "admin" can execute this
operand and have permission to change passwords for accounts other than
their own.
Password contains the minimum required number of lowercase characters.
Password contains the minimum required number of uppercase characters.
Password contains the minimum required number of numeric characters.
Password contains the minimum required number of punctuation characters.
Password must be between minlength and 40 characters long.
Password may not contain the colon (:) character.
Password must satisfy repeated and sequential character constraints.
If you are changing your own password, you are prompted to enter the old password and, if your
entry is valid, you are prompted to enter the new password.