fastboot

Reboots the Control Processor (CP), bypassing Power-On Self-Tests (POST).
Synopsis
fastboot
Description
Use this command to immediately reboot the CP. This command is similar to reboot, but skips POST
when the system comes back up, reducing boot time significantly.
If POST was previously disabled using the diagDisablePost command, then fastboot is the same as
reboot.
Notes
This command is not available on non-bladed systems except for the Brocade 4100 and 4900.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands
none
Examples
To reboot the Control Processor without executing power-on self test (POST) on startup:
See Also
diagDisablePost, diagEnablePost, reboot
Fabric OS Command Reference
53-1001186-01
switch:admin> fastboot