On the Specify Device Admin User Name/Password and One Time Password screen,
6.
perform the following tasks:
a.
Make a note of the automatically generated Unique External ID for the device.
This ID number represents the device within the management system. The device
administrator will need this ID to configure connectivity between the device and
NSM.
b.
Specify the administrator user name and password for the SSH connection. This
name and password must match the name and password already configured
on the device.
c.
Specify the First Connection One Time Password (OTP) that authenticates the
device. Make a note of this password. The device administrator will need it to
configure the connectivity between the device and NSM.
NOTE: All passwords handled by NSM are case-sensitive.
d.
Click Finish to complete the Add Device wizard and include the new device in
the Device Manager list.
Verify in the Device List tab that the new device is visible and has the connection
7.
status "Never connected."
Give the unique external ID and the one-time password to the device manager.
8.
Configure and Activate Connectivity on a JUNOS Device
The device administrator must identify the device to the management system and initiate
the connectivity:
Log on to the JUNOS device.
1.
At the command-line prompt, identify the management system by device name,
2.
device ID, and HMAC.
For devices running the 9.0 version of the operating system, use the following
command syntax:
set system services outbound-ssh application-id <name> secret <string>
services netconf device-id <external-id from nsm> <nsm device server ip>
port 7804
For example:
% set system services outbound-ssh application-id nsm-wei secret 123456789
services netconf device-id abcdef 10.150.42.16 port 7804
For devices running the 9.1 and later versions of the operating system, use the
following command syntax:
set system services outbound ssh client <name> secret <secret string>
services netconf device-id <external-id from nsm> <nsm device server ip>
port 7804