Slotpoweron - Brocade Communications Systems 8 Command Reference Manual

Fabric os command reference manual supporting fabric
Hide thumbs Also See for 8:
Table of Contents

Advertisement

2

slotPowerOn

slotPowerOn
Restores power to a slot.
Synopsis
slotpoweron slot
Description
Use this command to turn on the power to a blade unit. The slot must have a valid blade unit
present and the blade unit must be currently powered off. The slotShow command reports such
slots as being in the state of INSERTED, NOT POWERED ON.
Note
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands
This command has the following operand:
slot
Examples
To power on blade unit 3:
See Also
slotPowerOff, slotShow
876
Specify the slot number of the blade to be powered on. This operand is
required.
switch:admin> slotpoweron 3
Powering on slot 3.
Fabric OS Command Reference
53-1001764-02

Advertisement

Table of Contents
loading

Table of Contents