Shellflowcontrolenable - Brocade Communications Systems 8 Command Reference Manual

Fabric os command reference manual supporting fabric
Hide thumbs Also See for 8:
Table of Contents

Advertisement

2

shellFlowControlEnable

shellFlowControlEnable
Enables XON/XOFF flow control on the console serial port.
Synopsis
shellflowcontrolenable
Description
Use this command to enable XON/XOFF flow control to the shell task. Flow control is disabled by
default.
Because this command changes the flow control on the console serial port, it must be executed
from a session that is logged in from the console serial port. This command cannot run from a
Telnet session.
This setting is saved in the configuration database; therefore, it is persistent across reboots and
power cycles.
Notes
On dual-CP systems, a reboot on the standby CP is required for this command to take effect. No
action is required on the active CP.
If flow control is enabled and if the console output is suspended for an extended period of time, the
switch might reboot. It is recommended to disable the flow control, using shellFlowControlDisable.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
Operands
none
Examples
To enable flow control:
See Also
shellFlowControlDisable
874
switch:admin> shellflowcontrolenable
Enabling flowcontrol
flow control is now enabled