Printronix L7032 User Manual page 158

Printronix l7032: users manual
Hide thumbs Also See for L7032:
Table of Contents

Advertisement

graphics, symbols, or multinational characters. For example, to print Cyrillic, the user would
s
elect a Cyrillic set. To print Italian, the user would select a different set.
Unicode allows any character to be selected without switch
a different number for every character in all languages. Th
for multinational
printing.
UTF
-8 is a popular encoding of Unicode in which the first 128 characters are still occupied by th
ASC
II set. This makes it backwards compatible with older applications which use only ASCII
dat
a. It also allows the printing of all Unicode characters.
UTF-8 enc
oded Unicode can be enabled on the printer from the front panel or from a host
command in t
he LP+, PGL, or ZGL emulation.
Cmd Resolution
Low
Resolution. Sets a low command resolution mode.
Hig
h Resolution. Sets a high command resolution mode.
The
factory default is Low Resolution.
Copy Count
Determines the number of identical copies of each physical page that will be printed.
The range is 1-999, and the factory default is 1.
Data Bit 8
Enable. The PI line is not passed directly from host to printer; all 8 bits are used for data bits,
and characters in the hex 80-FF range can be accessed.
Disable. When the host P
the PI line, disable data bit 8, and enable the Host PI configuration option (under the PI
Ignored option).
Data bit 8 is interpreted as either data bit 8 or PI signal, but
data bit 8, data bit 8 has priority over the PI signal, and all d
access character data and not to interpret PI line data.
Conversely, when
reserved for use as the PI function, and you cannot access characters in the hex 80-FF range.
Therefore, to access characters in the hex 80-FF range, data bit 8 must be enabled.
The
factory default is Enable.
Error Markers
Enable. Prints the following error markers for those elements that print beyond the page
boundaries:
>> for elements that begin off the right side of the page;
<< for elements that begin at the indicated position but end off the page;
♦ for elements where the starting position of the command contains an error other than an
off-page error.
Disable.
The
factory default is Enable.
154
I lin
e is enabled, data bit 8 internally indicates PI line status. To use
data bit 8 is disabled and the PI signal is used, data bit 8 of the data is
in
g character sets because it specifies
us Unicode has become the standard
never both. Whe
ata above hex 7F is used to
e
n enabled as

Advertisement

Table of Contents
loading

Table of Contents