Omron NSJ CONTROLLERS - 03-2008 Operation Manual page 96

Nsj controllers
Table of Contents

Advertisement

System Configuration
Products Used in the System Configuration
Name
NSJ-series NSJ Controller
Memory Cards (for Controller Sec-
tion or Display Section, optional)
Programming
USB port
Device Connecting
Cables
RS-232C port XW2Z-200S-CV
Ethernet port
Battery Set
Expansion Units
NSJ I/O Con-
trol Unit
NSJ Control-
ler Link Unit
NSJ Ethernet
Unit
Note
Model
NSJ@-@@@@-
I/O capacity: 1,280 points, Program capacity: 60K steps, data
G5D
memory capacity: 128 Kwords (DM Area: 32 Kwords, EM Area:
32 Kwords × 3 banks)
NSJ@-@@@@-
I/O capacity: 640 points, Program capacity: 20K steps, data
M3D
memory capacity: 32 Kwords (DM Area: 32 Kwords, EM Area:
None)
HMC-EF372
Flash memory, 30 MB
HMC-EF672
Flash memory, 64 MB
HMC-AP001
Memory Card Adapter
---
Use an off-the-shelf USB cable with a type B connector and a
cable length of 5 m or less.
DOS D-sub 9-pin connector, cable length: 2.0 m. A connector
with ESD countermeasures is used.
XW2Z-500S-CV
DOS D-sub 9-pin connector, cable length: 5.0 m. A connector
with ESD countermeasures is used.
---
Use an off-the-shelf 10Base-T or 100Base-T cable.
CJ1W-BAT01
---
NSJW-IC101
Enables connecting CJ-series Expansion Racks. Provides the
same functionality as a CJ-series I/O Control Unit (CJ1W-IC101).
NSJW-CLK21-V1 Adds a Controller Link port. Provides the same functionality as a
CJ-series Controller Link Unit (CJ1W-CLK21-V1).
NSJW-ETN21
Adds an Ethernet port. Provides the same functionality as a CJ-
series Ethernet Unit (CJ1W-ETN21).
The following products are used when mounting an NSJ I/O Control Unit to
the NSJ Controller and connecting CJ-series Expansion Racks.
Name
Model
NSJ I/O
NSJW-IC101
Control Unit
I/O Interface
CJ1W-II101
Unit
CS/CJ-
CS1W-CN313
series I/O
CS1W-CN713
Connecting
CS1W-CN223
Cables
CS1W-CN323
CS1W-CN523
CS1W-CN133
CS1W-CN133B2
CJ-series
CJ1W-PA205R
Power Sup-
ply Units
CJ1W-PA205C
CJ1W-PA202
CJ1W-PD025
CJ1W-PD022
Specifications
Specifications
Enables connecting CJ-series Expansion Racks to
the NSJ Controller. (Connected to an I/O Interface
Unit (CJ1W-II101) on a CJ-series Expansion Rack
using a CS/CJ-series I/O Connecting Cables.)
One I/O Interface Unit is required on each CJ-
series Expansion Rack. One End Cover is included.
(Connected to the previous I/O Interface Unit or the
NSJ I/O Control Unit using a CS/CJ-series I/O Con-
necting Cable.)
Connect an I/O Control Unit (NSJW-IC101)
to an I/O Interface Unit (CJ1W-II101) or
connect two I/O Interface Units.
100 to 240 V AC (with RUN output), output capac-
ity: 5 A at 5 V DC, 0.8 A at 24 V DC
100 to 240 V AC (with replacement notification),
output capacity: 4.6 A at 5 V DC, 0.8 A at 24 V DC
100 to 240 V AC, output capacity: 2.8 A at 5 V DC,
0.4 A at 24 V DC
24 V DC, output capacity: 5 A at 5 V DC,
0.8 A at 24 V DC
24 V DC (not insulated), output capacity:
2.0 A at 5 V DC, 0.4 A at 24 V DC
Section 3-2
0.3 m
0.7 m
2 m
3 m
5 m
10 m
12 m
65

Advertisement

Table of Contents
loading

Table of Contents