Nomenclature and Functions
Pin no. Setting
5
ON
RS-232C port communications parameters
set using the CX-Programmer (Toolbus only)
are used.
OFF
RS-232C port communications parameters
set in the PLC Setup are used.
6
ON
User-defined pin. Turns ON the User DIP
Switch Pin Flag (A39512).
OFF
User-defined pin. Turns OFF the User DIP
Switch Pin Flag (A39512).
7
Easy backup type
8
Keep
---
turned
OFF.
Note
Controller Section
Memory Card
Memory Card Power
Supply Switch
Serial Port C
Expansion Unit Connector
Function
Table 1
DIP switch pin
Easy backup type
Pin No. 7
ON
Writing from Controller Section
to Memory Card.
Writing from Memory Card to
Controller Section.
OFF
Verifying contents of Memory
Card against the contents of the
Controller Section.
1. The following data cannot be overwritten when pin 1 is ON:
• All parts of the user program (programs in all tasks)
• All data in the parameter area (such as the PLC Setup and I/O tables)
When pin 1 is ON, the user program and parameter area will not be cleared
when the memory clear operation is performed from the CX-Programmer.
2. The Controller Section will not enter any mode except PROGRAM mode
after backing up data to a Memory Card using the easy backup operation.
To enter RUN or MONITOR mode, turn OFF the power supply, turn OFF
pin 7, and then restart the NSJ Controller. This will enable changing the op-
erating mode as normal.
A Memory Card can be used to back up all Controller Section data, including
the user program, parameters, I/O memory, and comment memory files. Auto-
matically transferring data from the Memory Card at startup can also be used
to enable batteryless operation.
Press the power supply switch to disconnect power before removing the Mem-
ory Card. Also, press the Memory Card Power Supply Switch to perform an
easy backup operation.
Serial port C has the same functionality as the RS-232C port on a CJ1-H CPU
Unit with unit version 3.0. The following serial communications modes are
supported: Toolbus, Host Link, NT Link, No-protocol, and Serial Gateway.
An Expansion Unit can be mounted here.
Usage
Turn ON to use the RS-232C port for the CX-
Programmer in Toolbus mode.
Set pin 6 to ON or OFF and use A39512 in
the program to create a user-defined condi-
tion without using an Input Unit.
Determines the type of easy backup to be
performed. See Table 1, below.
Press the Memory Card Power
Supply Switch for 3 s while
power is ON.
Turn ON the power supply to the
NSJ Controller.
Note This operation is given pri-
Press the Memory Card Power
Supply Switch for 3 s while
power is ON.
Section 4-1
Default
OFF
OFF
OFF
OFF
Required operations
ority over automatic trans-
fer (pin 2 is ON) at startup.
75