Omron NSJ CONTROLLERS - 03-2008 Operation Manual page 85

Nsj controllers
Table of Contents

Advertisement

Specifications
Item
Error check
Error log
Clock
Power OFF detection time
Power OFF detection delay
time
Memory protection
Sending commands to a Host
Link computer
Remote programming and
monitoring
Eight-level communications
Storing comments in Control-
ler Section
54
Specifications
User-defined errors (i.e., user can define fatal errors and
non-fatal errors)
The FPD(269) instruction can be used to check the execution
time and logic of each programming block.
FAL and FALS instructions can be used to simulate errors.
Up to 20 errors are stored in the error log. Information
includes the error code, error details, and the time the error
occurred.
The Controller Section can be set so that user-defined FAL
errors are not stored in the error log.
Provided on all models.
Accuracy:
Ambient temperature
25°C
Note The accuracy will vary with the temperature.
Note Used to store the time when power is turned ON and
when errors occur.
2 ms
0 ms (fixed)
Held Areas: Holding bits, contents of Data Memory and
Extended Data Memory, and status of the counter Comple-
tion Flags and present values.
Note If the IOM Hold Bit in the Auxiliary Area is turned ON,
and the PLC Setup is set to maintain the IOM Hold Bit
status when power to the NSJ Controller is turned ON,
the contents of the CIO Area, the Work Area, part of
the Auxiliary Area, timer Completion Flag and PVs,
Index Registers, and the Data Registers will be saved.
FINS commands can be sent to a computer connected via
the Host Link System by executing Network Communications
Instructions from the Controller Section.
Host Link communications can be used for remote program-
ming and remote monitoring through a Controller Link Sys-
tem or Ethernet network.
Host Link communications can be used for remote program-
ming and remote monitoring from devices on networks up to
eight levels away (Controller Link Network or Ethernet Net-
work).
I/O comments can be stored as symbol table files in the
Memory Card in the Controller Section, EM file memory, or
comment memory (see note).
Note Comment memory is supported for CX-Programmer
version 5.0 or higher.
CJ Series Operation
Manual (W393): 11-2-5
Error Messages
CS/CJ Series Program-
ming Manual (W394):
6-5 Diagnostic Func-
tions and 6-5-3 Failure
Alarm Functions
CS/CJ Series Program-
ming Manual (W394):
6-4-1 Error Log
CS/CJ Series
Programming Manual
Monthly error
−1.5 min to +1.5 min
(W394): 6-4-5 Clock
Functions
CJ Series Operation
Manual (W393): 10-3
Power OFF Operation
CS/CJ Series Program-
ming Manual (W394):
6-4-4 Power OFF
Detection Delay Time
CJ Series Operation
Manual (W393): 9-2-3
Data Area Properties
CJ Series Operation
Manual (W393): 2-5-2
Systems
CJ Series Operation
Manual (W393): 2-5-3
Communications Net-
work System
CS/CJ Series Program-
ming Manual (W394):
6-4-7 Remote Program-
ming and Monitoring
CJ Series Operation
Manual (W393): 2-5-2
Systems
I/O comments: CX-Pro-
grammer Ver. 5.0 Oper-
ation Manual (W437)
Storing comments in
CPU Unit: CS/CJ
Series Programming
Manual (W394)
Section 3-1