6-6

Aggregate Status Scan

The following display appears for the Aggregate Status Scan:
STATUS SCAN FOR AGGREGATE
________________________________________________________________________
* ALARM SCAN
The Aggregate Status Scan reports the following items:
LOOPBACK
LCL indicates that the aggregate interface of the Redundancy Control Plus module is in a local
loopback condition. RMT indicates that the aggregate interface of the Redundancy Control Plus
module is in a remote loopback condition. Off indicates that the system is not in a loopback mode.
ACO
ON indicates that Alarm Cut-Off' has been selected for the Aggregate Interface, and no alarms are
being reported. OFF indicates that Alarm Cut-Off has not been selected for the Aggregate Interface.

Power Supply Status Scan

The following display appears for the Power Supply Status Scan.
STATUS SCAN FOR POWER SUPPLY
________________________________________________________________________
* ALARM SCAN
The Power Supply Status Scan reports the following items:
FAULT
ON indicates that a problem exists with the MEGAMUX PLUS power supply. Off indicates that
the power supply voltage levels are normal.
ACO
ON indicates that Alarm Cut-Off has been selected for the power supply, and no alarms are being
reported. OFF indicates that Alarm Cut-Off has not been selected for the power supply.
036R660-000, Issue 10
:
NODE M
LOOPBACK
:
OFF
ACO
:
ON
- NO ALARMS -
:
NODE M
FAULT
:
OFF
ACO
:
OFF
- NO ALARMS -
Status Scan
NODE S
OFF
ON
NODE S
OFF
OFF