6-4
T/R INSERV
PRI (primary) or SEC (secondary) may be reported: This reports whether the primary or secondary
Transmit/Receive Logic Plus module is operating (in non-redundant systems, PRI is always report-
ed).
COMMON FAULT
ON or OFF may be reported. OFF indicates that no alarm conditions exist for the common set; ON
indicates that an alarm condition exists. In a non-redundant system, ON is always reported.
CURRENT CFG
This item reports which TDM configuration is currently in use.
ACO
ON indicates that Alarm Cut-Off has been selected for the common set, and alarms are not being
reported. OFF indicates that Alarm Cut-Off has not been selected.

AUTO FRAME Status Scan

The following display appears for the AUTO FRAME module:
The AUTO FRAME status scan reports the following items:
STATUS SCAN FOR AUTO FRAME
__________________________________________________________________________
* ALARM SCAN
INSERVICE
P R I prim ary) or S E C secondary) m ay be rep orted . T his item in dicates w hether the p rim ary or secondary
A U T O F R A M E P lus m od ule is operatin g. (In non-redundant system s, PR I is alw ays reported.)
PRI ALARM
O N indicates that an alarm condition exists in the prim ary A utofram e Plus m odule, or that there is no A U T O
F R A M E Plu s m odule in the prim ary A U T O F R A M E slot. O F F indicates that no alarm co nditio ns are presen t.
SEC ALARM
O N indicates that an alarm co nditio n exists in the secondary A utofram e P lus m odule, or that there is n o A U T O
F R A M E P lus m od ule in the seco ndary A U T O F R A M E slo t. O F F indicates that no alarm con dition s are
present.
036R660-000, Issue 10
REDUNDANCY UPDATE
NOTE
Upon resumption of link down, a false autoframe status indicating
remote revision of "2.00" was possible. This has been corrected in
versions 3.11, 2.11, and A111.
:
INSERVICE
:
PRI ALARM
:
SEC ALARM
:
ACO
:
SOFTWARE REV :
- NO ALARMS -
Status Scan
NODE M
NODE S
PRI
PRI
OFF
OFF
OFF
OFF
OFF
OFF
2.01
2.01
LOCAL
REMOTE