6-8
When the ALARM SCAN or CONTROL STATES SCAN are selected from the SPECIFIC STA-
TUS MENU, the displays are as follows:
ALARM SCAN
Reports the most recent alarm messages associated with each component. After displaying the mes-
sages, you are allowed to delete messages already displayed.
CONTROL STATES SCAN
Displays the names and states of each channel control signal. Four possible signal states are report-
ed as follows.
036R660-000, Issue 10
NOTE
If a Channel Status Scan is selected for a PCM channel, the display
will report only the alarm messages. The Control Status Scan is not
applicable for PCM channels.
ON - the signal is logically ON, under control of channel-connected equipment.
OFF - the signal is logically OFF, under control of channel-connected equipment.
F-ON - the signal is forced to an ON state by the MEGAMUX PLUS system, either
through the configuration or diagnostics.
F-OFF - the signal is forced to an OFF state by the MEGAMUX PLUS system, either
through the configuration or diagnostics.
NOTE
If applicable, "CONFIGURATION ERROR" or "OUT OF SYNC" will
appear adjacent to the "CHAN #" entry.