The following instructions apply to the Rcv dB Levels routine:
1.
1. Select the Channel diagnostics and Data Path Test. Use the up or down cursor position keys
to select RCV dB. Use the left and right cursor position keys to move the cursor to the Data
Origin field. Use the up and down cursor position keys to select the Node M or Node S VL-
BRV Channel Module for output level adjustment.
2.
When a node is selected, press Return. The following appears:
Use the up and down cursor position keys to select a level. The selected level becomes active in the
system. To exit the routine, enter Control X. The following message is displayed:
SAVE CHANGES Y/N
If you enter Y, the level is stored in non-volatile memory for each configuration in which the VL-
BRV Channel Module has been configured. The channel output remains at the selected level until
the routine is applied to the VLBRV Channel Module again, or another configuration is activated.
If you enter N, the configuration is not stored. However, the VLBRV Channel Module's output level
remains at the selected level until the routine is applied to the channel again, or any configuration
is activated. The Channel Diagnostics menu returns to the screen, and another diagnostic routine
are applied to the VLBRV Channel Module.