Analog Output; Calculating Measured Value From Current Output - MICRO-EPSILON confocalDT IFD2410 Series Operating Instructions Manual

Table of Contents

Advertisement

Set Sensor Parameters, Web Interface
6.5.4

Analog Output

Only one measured value can be transmitted. The resolution of the analog output is 16 bit.
Output signal
01DIST1 / ... 01DIST6 / ... The data selection depends on the current setting and includes the results
Output range
4 ... 20 mA / 0 ... 5 V /
0 ... 10 V
Scaling
Standard scaling
Two-point scaling
The first value corresponds to the start of the measuring range and the second value to the end of the measuring range.
If the analog range needs to be moved, we recommend using the zeroing or mastering function.
Two-point scaling enables the user to specify separate start and end values (in mm) for the sensor's measuring range.
The available output range of the analog output is then spread between the minimum and maximum measured values.
This allows for decreasing analog characteristics,
10.9 V
10 V
Analog
output
0 V
LED "Range"
23,8 mA
20 mA
Analog
output
4 mA
Fig. 68 Scaling the analog signal
6.5.4.1

Calculating Measured Value from Current Output

Current output (without mastering, without two-point scaling)
Variables
I
= Current [mA]
OUT
MR = measuring range
[mm]
d
= Distance [mm]
confocalDT IFD2410/2411/2415
from the calculation modules as well as the distance values.
Either the voltage or the current output can be used on the IFD241x.
Scaling to 0 ... Measuring range
Start of range
corresponds to (in mm):
End of range
corresponds to (in mm):
see Fig.
Standard characteristic
Start of measuring
Target
range
Target in measuring range
Error
End of
EMR
range
Value range
[3.8; <4] SMR reserve
[4; 20] measuring range
[>20; 20.2] EMR reserve
{/1/2/3/6/10}
[-0.01MB; 1.01MB]
Value
Value
68.
End of measuring range
Error
Two-point
scaling
Start of
SMR
range
Formula
(I
d =
- 4)
OUT
* MR
16
Page 71

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the confocalDT IFD2410 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents