Appendix | ASCII Communication with Controller
A 5.3.2
User level
A 5.3.2.1
Change User Level
LOGIN <Password>
Enter the password to access another user level. There are the following user levels:
- USER: Read access to all elements + use of web diagrams
- PROFESSIONAL: Read/write access to all elements
Command is mapped in the SDO 0x3001.
A 5.3.2.2
Switch to User Level
LOGOUT
Set user level to USER.
Command is mapped in the SDO 0x3001.
A 5.3.2.3
User Level Query
GETUSERLEVEL
Queries the current user level.
Possible outputs, see
Chap. A
A 5.3.2.4
Set Standard User
STDUSER USER|PROFESSIONAL
Sets the standard user who is logged in after the system starts.
A 5.3.2.5
Change Password
ASSWD <Old password> <New password> <New password>
Change the password for the PROFESSIONAL user. The factory standard password is "000".
For this, the old password must be entered and the new password must be entered twice. If the new passwords do not
match, an error message will be output. The password function is case-sensitive. A password may only contain the let-
ters A to Z and numbers without umlauts/special characters. The maximum length is limited to 31 characters.
A 5.3.3
Level of Multifunction Inputs
MFILEVEL HTL | TTL
Selection of input level of the multifunction inputs. (MFI).
- HTL: HTL level
- TTL: TTL level