Function Variants
6.4.4 Standard Operating Sequence
This item reflects a typical operating sequence of a crane scale:
Action
1. DISOMAT B plus must
be in home position!
Set display type: 'NET'
2.Hook on ropes or cross-
members, acquire tare.
3. Pick up load.
4.If need be, enter weigh
packaging or shopping
pallets as manual tare
value, or select value from
list of Fixed Tare values.
Not necessary if it
em 2 has
be
en performed.
5. If need be, enter string.
6. Weigh and print.
7. Totally relieve scale.
8. Clear tare memory.
®
DISOMAT
Opus – Operating Manual
© Schenck Process GmbH, Darmstadt
Display (e.g.)
G
0.0 kg
G
103.5 kg
Net T
0.0 kg
Net T
205.0 kg
t of
do.
do.
do.
do.
G 308.5 kg
Key; Comments
If scale display does not read zero:
->'Zero Scale' key
'Acquire Tare' key
Scale is tared
Scale shows NET weight.
'Manual Tare In
put' key or 'Fixed
Tare' selection
or
A quire input with key
c
'Enter String' key
+
Print or store weigh data. Relieve
crane to perform next weighing
operation.
Weighing is complete. Remove load
from scale, and scale is ready for
next weighing operation.
0630
BV-H2313 GB
Crane Scale
- 111 -
Need help?
Do you have a question about the Disomat Opus and is the answer not in the manual?
Questions and answers