Function Variants
Parameter Name Default Required
Setting
Block 'PLS-AOut'
Reference value
20
Block 'Analog Output'
Analog output
OFF

6.3 Discharge Scale

6.3.1 General Functioning

Before operating a discharge scale, make yourself familiar with the
general functioning of your DISOMAT.
The discharge scale is designed to batch material out of a weigh hopper. Single and
multiple discharge operations are possible.
Filling
DISOMAT controls a fill unit for discharging in full feed and dribble feed until setpoint
is reached. the amount fed out is checked for tolerance; if required, make-up filling
takes place. In case of overfill, an event message is output.
To start filling,
Press F1 key, or
Set input contact 1, or
Send EDP command or
PLS contact.
®
DISOMAT
Opus – Operating Manual
© Schenck Process GmbH, Darmstadt
Recommended
Comments
Setting
= MAX
Scaling the parallel output of the analog
reference value
output to the PLS analog output 1.
4-20 mA
Discharge Scale
0630
BV-H2313 GB