Summary of Contents for Schenck process Disomat Opus
Page 1
® DISOMAT Opus Operating Manual BV-H2313 GB...
Page 2
Schenck Process GmbH Pallaswiesenstraße 100, 64293 Darmstadt, Germany www.schenckprocess.com All rights reserved. Any reproduction of this documentation, regardless of method, without prior permission by Schenck Process GmbH in writing, even by excerpt, is prohibited. Subject to change without prior notice.
What Do I Do If A Fault Occurs? • First read Chapter 7 and try to remedy fault. If you wish to get in touch with Schenck Process GmbH, see list of contacts at the Copyright page. What If I Meet Terms I Don't Know? •...
DISOMAT Overview Control Elements B) 'DISOMAT Opus mini' This design has a reduced keyboard, which means that it is operated differently. You can find the details further below in the keyboard section. 3.2.2 Display The display consists of an LC display with 20 characters.
Page 21
('Insert'). Normally you are in Overwrite mode; the PC typical Insert mode is not provided for. B) 'DISOMAT Opus mini' The 'DISOMAT Opus mini' design has reduced keyboard: Input block: Control block: Direction keys 3 Function keys [OK] key...
L:14.07.06 08:48 L = loading date/loading time U:<DISOPLAN User> U = user (from the loading program) C:Schenck Process GmbH C = Company (ditto) The log file can have as many as 60 entries. 4.2.4.3 Fct. 53:Display Type Use function to determine the weight display default settings: •...
The test ends after all lines have been called up. *) Access Code for Internet Download Schenck Process offers its customers the latest documents and software for download via Internet. Files are stored in a protected area accessible after access code input.
• CALIBRATION - Set and calibrate weighing system. Before calling functions (see Item 5.4), enter Calibration password. As convenient servicing tool, SCHENCK PROCESS have developed the DISOPLAN PC program. Calling up setting mode Call up menu tree, go to function...
XDO Contact 1 Outputs 1-4 Common root Operating sequence can be set to "Weighing Complete" (GREEN exit signal) via EDP command. DISOMAT Opus outputs can control 230V lights directly. Cables of 1.5 mm cross- section per core can be connected directly.
Page 150
Setting Range With Multi-Range Scale 88 Setting Using Calibration Password 73 Setting Using Configuration Password 60 Setting Using Parameter Password 44 Signal Control Using DISOMAT Opus-ZEUS 128 Single-range scale 81 Standard Operating Sequence 97, 104, 111, 116, 121 transmission parameter 63...
Need help?
Do you have a question about the Disomat Opus and is the answer not in the manual?
Questions and answers