Function
Parameter name
code
Carrier frequency
P22.04
switching point 1
Carrier frequency
P22.05
switching point2
PWM modulation
P22.06
method
P22.07
DPWM switching point
P22.08
Modulating limit
P22.10
AVR function
VFD500 high performance vector control frequency inverter user manual
Description
0.00Hz~600.00HzWhen the carrier
frequency is adjusted according to the
output frequency, the carrier frequency
set by P22.02 is used when the output
frequency is lower than this set value.
0.00Hz~600.00Hz When the carrier
frequency is adjusted according to the
output frequency, the carrier frequency
set by P22.03 is used when the output
frequency is higher than this set value.
0:SVPWM
It is normally used
1:SVPWM+DPWM
Using this modulation method can reduce
the switching loss of the inverter and
reduce the probability of overheating
alarm of the inverter; however, the
electromagnetic noise of the motor in the
medium speed section will be too large.
2:PWM at random
The electromagnetic noise generated by
the motor is white noise, not a sharp
squeak.
3:SPWM
It is only used in special situation
10%~100%(modulation percentage)
When P22.06 is set to 1, increasing this
setting value can reduce the
electromagnetic noise in the middle
speed section.
100%-110%
It is used to define the duty cycle of the
inverter side IGBT. Overmodulation is
allowed when it is set to 100% or more,
and the allowable overmodulation is
deepened when the set value is
increased from 101 to 110.
0:diabled
1:enabled
When the AVR function is enabled, the
effect of the DC bus voltage change on
the output voltage can be eliminated.
- 89-
Default
Property
10.00Hz
50.00Hz
0
30%
105%