Chapter 5 Function code
Function
Parameter name
code
number
CANopen send frame
r31.14
number
32 Group Profinet communication parameter
P32.00
Device name
P32.01
IP1
P32.02
IP2
P32.03
IP3
P32.04
IP4
P32.05
MAC1
VFD500 high performance vector control frequency inverter user manual
Description
CANopen is not saved after power off
The number of frames sent by CANopen
is not saved after power off
When the setting value is 0, it is
configured by the host computer and no
other display is made
When the setting value is 1~255, the
corresponding device name is mtpn-1~
mtpn-255
Note: Effective after power on again
IP address format: IP1. IP2. IP3. IP4
When P32.01~P32.04 is set to 0
After power-on, the PN card will write the
IP address stored in the card to the drive
for display
When you need to fix the IP address of
the corresponding drive, set
P32.01~P32.04 manually (effective after
power on)
The standard MAC address is 6 bytes,
P32.05~P32.07 corresponds to the MAC
address of two bytes, and the
corresponding MAC address sequence
is M AC1H-MAC1L-MAC2H-MAC2L-
MAC3H-MAC3L ( H-high 8 bits, L-low 8
bits).
When P32.05~P32.07 is set to 0
After power-on, the PN card will write the
address stored in the card to the drive for
display
Note:
1.
Each port occupies an MAC
address, it is recommended that
the P32.07 bits not be modified,
and the modification starts from
10 bits
The MAC modification must be
2.
powered back on to take effect
3.
The MAC address should be
- 103-
Default
Property
-
0
0
0