Chapter 5 Function code
Function
Parameter name
code
P03.06
Deceleration time3
P03.07
Acceleration time4
P03.08
Deceleration time4
The VFD500 provides four groups of acceleration and deceleration time. The actual acceleration / deceleration time can
be selected by different methods such as DI terminal, output frequency and PLC running segments. Several methods can not
be used at the same time. Factory default is to use acceleration / deceleration time
1.DI terminal select acceleration and deceleration time of the mapping table is as follows::
Acceleration and
deceleration time
DI terminal 2
Ineffective
Ineffective
Effective
Effective
The schematic diagram of selecting acceleration / deceleration time according to the output frequency is as follows:
Output frequency
Acceleration time
switch frequency1
(P03.18)
Deceleration time
switch frequency1
(P03.19)
Other ways to select acceleration / deceleration time can be found in the description of relevant parameters。
Jog Acceleration
P03.09
time
Jog Deceleration
P03.10
time
S-curve Acceleration
P03.11
begin time
S-curve Acceleration
P03.12
arrival time
S-curve Deceleration
P03.13
begin time
VFD500 high performance vector control frequency inverter user manual
Description
0.01~60000s same as P03.02
0.01~60000s same as P03.01
0.01~60000s same as P03.02
Acceleration and
deceleration time
Acceleration and deceleration time
DI terminal 1
Acceleration and deceleration time
Ineffective
Acceleration and deceleration time
Effective
Acceleration and deceleration time
Ineffective
Acceleration and deceleration time
Effective
Acceleration
time1
Acceleration time2
Time Setting same as P03.01
Time Setting same as P03.02
Setting value depend on P03.16
P03.16 = 2, 0.01~30.00s;
P03.16 = 1, 0.1s~300.0s;
P03.16 = 0, 1s~3000s
SAME AS P03.11
SAME AS P03.11
- 53-
terminal 1(P03.01,P03.02)
terminal 2(P03.03,P03.04)
terminal 3(P03.05,P03.06)
terminal 4(P03.07,P03.08)
Deceleration time1
Deceleration time2
t
Default
Property
Depend
on model
Depend
on model
Depend
on model
6.00s
10.00s
0.50s
0.50s
0.50s