Veikong VFD500 Series User Manual page 77

High performance vector and torque control frequency inverter
Hide thumbs Also See for VFD500 Series:
Table of Contents

Advertisement

Chapter 5 Function code
Function
Parameter name
code
Multi-point VF Frequency
P12.03
1(F1)
Multi-point VF Voltage
P12.04
1(V1)
Multi-point VF Frequency
P12.05
1(F2)
Multi-point VF Voltage
P12.06
2(V2)
Multi-point VF Frequency
P12.07
3(F3)
Multi-point VF Voltage
P12.08
3(V3)
P12.09
Torque boost
Automatic torque boost
When P12.09=0=Automatic torque boost, inverter will automatically compensate output voltage to improve torque
in low frequency as per actual load ,it is useful for linear VF curve
Manual torque boost
When P12.09 not 0,it means manual torque output. Output frequency 0 torque increasing
value=p12.09*motor stator resistance *rated excitation current, increasing value will be gradually decreased
as frequency increase ,if higher than 50% of motor rated frequency, increasing value will be zero
Notice: manual torque boost is useful to linear and power curve
P12.11
Slip compensation gain
Slip compensation filter
P12.12
time
VFD500 high performance vector control frequency inverter user manual
Description
multi-point VF curve F0(P12.01)~
multi-point VF curve F2(P12.05)
0.0%~100.0%
multi-point VF curve F1(P12.03)~
multi-point VF curve F3(P12.08)
0.0%~100.0%
multi-point VF curveF2(P12.05)~
600.00Hz
0.0%~100.0%
0%~200% 0% is automatic torque
boost
0~200%
It is used to compensate the speed
drop of the asynchronous motor VF
control with load, and improve the
speed control accuracy. Please adjust
according to the following principles:
Increase the setting when the
motor speed is lower than the
target value with loading.
Reduce this setting when the
motor speed is higher than the
target value with loading,
0.01s~10.00s
It is used to adjust the speed and
stability of the VF control response to
the load.
Decrease this setting when the
load response is slow.
Increase this setting when the
speed is unstable
- 75-
Default
Property
50.00Hz
100.0%
50.00Hz
100.0%
50.00Hz
100.0%
0%
100%
1.00s

Hide quick links: