Chapter 5 Function code
Function
Parameter name
code
r11.00
Motor type
P11.02
Motor rated power
P11.03
Motor rated voltage
P11.04
Motor rated current
P11.05
Motor rated frequency
P11.06
Motor rated RPM
P11.07
Motor rated power factor
r11.08
Motor rated torque
Number of motor 1 pairs
r11.09
of pole
P11.10
Auto-tune/self-learning
VFD500 high performance vector control frequency inverter user manual
11 Group Motor 1 Parameter
Description
0:AC asynchronous motor
1:Synchronous motor(Special software)
See appendix parameter
0.1kW~800.0kW
when power is less than
1kw ,0.75kw set to 0.8 as per round
up principle ,0.55kw motor set 0.6
when change motor rated power,AC
drive will automatically set other
parameter of motor name plate and
motor model parameter be careful
to use
10V~2000V
P11.02<30kW:0.01A
P11.02>=30kW:0.1A
1.00Hz~600.00Hz
1~60000rpm
0.500~1.000
Read only,0.1Nm(P11.02<30KW);
1Nm(P11.02>30KW)
Read only, It will auto calculate as per
motor rated frequency and rated rotating
speed
0:no auto tuning
1:Stationary auto tuning of
Asynchronous motor
It is suitable in the cases when the motor
can not de-couple form the load. The auto
tuning for the motor parameter will impact
the control
accuracy.
2:dynamic or Rotational auto tuning of
Asynchronous motor
Comprehensive motor parameter
autotune
It is recommended to use rotation auto
tuning when high control accuracy is
needed.
- 72-
Default
Property
0
Depend
Depend
Depend
50.00Hz
Depend
Depend
-
-
0