Chapter 5 Function code
Function
Parameter name
code
P10.01
Encoder type
P10.02
Encoder line number
P10.03
AB pulse direction
Rotating ratio molecule
P10.07
between motor and
encoder
Rotating ratio
P10.08
denominator between
motor and encoder
When encoder is not installed on the motor rotor axis, asynchronous motor vector control with encoder is
effective by setting motor and encoder rotating speed ratio (P10.07 and P10.08)
For example:if motor rotating speed is 1500RPM and encoder speed 1000RPM,set P10.07=1500,
P10.08=1000.
Encoder offline
P10.09
detection time
Encoder rotation filter
P10.11
time
encoder feedback
r10.12
rotating speed
Encoder current
r10.13
position
VFD500 high performance vector control frequency inverter user manual
10 Group encoder type
Description
0: ABZ
1: ABZUVW
2: Rotary/resolver
3: sin/cos encoder
Consult factory when need PG card
1~65535
Rotary pulse number: 1024× rotary pair of
poles
0: forward, 1: reverse
If control mode is VC (with PG
card)we can get this value by auto
tuning for motor
We can run motor with open loop,
and observe r10.12 and r27.00 if they
are in the same direction, if not, then
change this value
1~65535
1~65535
0.0(not detecting)~10.0s
0~32 speed loop control cycle
Current rotating speed by measuring, unit:
0.01Hz/1Rpm
unit set by P21.17。
no symbolic number,Function code
r27.02:Bit5 for direction;keypad
indicator【REV】indicate direction
0 ~ 4*encoder pulse number -1
encoder current position refer Z pulse as
zero point, motor forward running and one
cycle to Z pulse ,then position to zero
- 70-
Default
Property
0
1024
0
1000
1000
2.0
1
-
-