Chapter 5 Function code
VFD500 has two inbuilt counters: Counter 1 is a 32-bit multifunction counter with electronic gears; counter 2 is a 16-
bit normal counter with no electronic gear function. Now take the counter 1 as an example to briefly explain its function
and use, and the counter 2 will not be specified.
The counter 1 receives the pulse signal through the terminal corresponding to the DI function "Counter 1 input",
and the pulse signal is used for the counter 1 counting after passing through the electronic gear. When the count
value reaches the set value (P45.04), the DO function "Counter 1 set value reached" is valid; when the count value
reaches the maximum value (P45.06), select whether to stop counting or reset the count according to P45.13. value.
The counter can also be reset by the DI terminal. When the DI Terminal is the "Counter 1 reset" function and the
terminal is valid, the counter 1 is reset.
For example: P45.04=3, P45.08=3, P45.09=1, the function of counter 1 is as shown below.
Counter input:
Counter1 before
electronic gear
Counter1 after electronic
gear
Set value arrival output
Counteer reset DI input
By setting a reasonable electronic gear, the counter 1 can realize functions such as fixed length in addition to
the counting function, and the user can flexibly use it in specific applications.
Function
Parameter name
code
Counter 2 actual
r45.10
value
P45.11
Counter 2 set value
Counter 2 maximum
P45.12
value
P45.13
Counter 1 control
VFD500 high performance vector control frequency inverter user manual
1 2 3
4 5 6
7 8 9
1
2
3
Description
Read only
When the counter 2 count value (after the
electronic gear) reaches this setting, the
DO function "Counter 2 set value reached"
is valid.setting range: 1~65535
1 to 65535, set the maximum value of
counter 2.
Setting range: 1~65535
Unit'digit: counting method
0: Stop counting after counting the
maximum value
1: Reset after counting the maximum
value, recount from 0
Ten'sdigit: the action after the counter
reaches the set value
0: continue to run
1: Free stop
2: Ramp to stop
3: Emergency stop
Hundred's digit : Power-down save option
0: Do not save the count value when power
is off
1: save the count value when power is off
- 121-
0
1 2 3 4
0
1
Default
Property
-
1000
65535
001