Chapter 5 Function code
Function
Parameter name
code
Any frequency
P08.08
reaching detection
amplitude 2
When the output frequency reaches positive or negative detection amplitude of frequency detection value,
DO outputs ON signal. VFD500 series inverter provides two parameters of any arrival frequency detection
value, used to set frequency value and frequency detection range.
Zero speed detection
P08.09
amplitude
Zero current detection
P08.10
level
Zero current detection
P08.11
delay time
When the output current ≤ zero current detection level, lasts for longer than zero current detection delay time,
DO terminal outputs ON signal.
VFD500 high performance vector control frequency inverter user manual
Description
0.0%~100.0% maximum frequency
(P01.06)
0.00H~5.00Hz
0.0%~100.0% rated motor current
0.000~30.000s
0.000~30.000s
Notice:When output current≤P08.10 and
endure P08.11 time, corresponding DO
output effective signal
- 68-
Default
Property
3.0%
0.25Hz
5.0%
0.100s