Chapter 5 Function code
Function
Parameter name
code
Torque setting over
P14.08
limit speed
P14.10
Static friction torque
Static friction torque
P14.11
compensation
P14.12
Dynamic friction factor
Dynamic friction
P14.13
starting value
Torque control upper
P14.15
limit frequency
acceleration time
Torque control upper
P14.16
limit frequency
deceleration time
Electricity meter count
r16.00
(32BIT)
r16.02
Output power
r16.03
Power factor
Electricity meter zero
P16.04
clearing
P16.05
Energy saving control
Energy saving voltage
P16.06
limit
P16.07
Energy saving filter time
VFD500 high performance vector control frequency inverter user manual
Description
0: Symmetrical torque command
After the motor speed exceeds the speed
limit value, the torque input source sets the
absolute value of the torque reference, and
the direction of the torque is always the
braking force.
1: Enter speed mode
After the motor speed exceeds the speed
limit value, enter the speed mode, and the
inverter will limit the speed to within the
speed limit value as much as possible.
0.0%~50.0%
0.00Hz~50.00Hz
It is used to overcome the static friction
force at the start, and the speed is higher
than P14.11 and the static friction torque
compensation is cancelled.
0.0%~50.0%
Dynamic friction at rated speed
Notice: motor sliding friction torque at rated
rotating speed
0.0%~50.0%
0.00~655.35
0.00~655.35
16 Group Energy saving control
Unit: KW/H
Unit:0.1kw, output power will be negative in
regen state
-1.000~1.000
0:no function;1111:clear to zero
0:disable
1:enable
0%~50%(0% means Energy saving control
disable and more than 0% means Energy
saving control enable
0.0~10.0s
- 80-
Default
Property
0
10.0%
1.00Hz
0.0%
0.0%
0.00
0.00
-
-
-
0
0
0%
2.0s