Veikong VFD500 Series User Manual page 81

High performance vector and torque control frequency inverter
Hide thumbs Also See for VFD500 Series:
Table of Contents

Advertisement

Chapter 5 Function code
Function
Parameter name
code
Torque control input
P14.00
source
P14.01
Torque digital setting
P14.02
Maximum torque
Torque reference
P14.03
ramp-up time
Torque reference
P14.04
ramp-down time
P14.05
Speed limit source
Digital setting of
P14.06
forward speed limit
value
Digital setting of
P14.07
reverse speed limit
value
VFD500 high performance vector control frequency inverter user manual
14 Group Torque control
Description
0:Digital setting(P14.01)
1:AI1
2:AI2
3:AI3(IO expansion board)
4:AI4(IO expansion board)
5:HDI
6:Communication
-200.0~200.0%
The torque reference greater than 0
indicates that the direction of the torque is
the same as the forward direction of the
motor; less than 0 indicates that the
direction of the torque is the same as the
reverse direction of the motor.
Benchmark 10.0%~300.0%
Notice: It is torque benchmarks as torque
reference for analog inputs and high
frequency pulse input also it is the ultimate
output torque during torque control.
0.000s~60.000s
Notice: The time for the torque reference to
increase from 0 to the rated torque of the
motor
0.000s~60.000s
Notice: The time for the torque reference to
decrease from the rated torque of the motor
to 0
Units: speed limit source selection
0: Digital setting (P14.06)
1: AI1
2: AI2
3: AI3 (expansion card)
4: Reserved
5: HDI
6: Communication
Ten's place: speed limit source symbol
0: unsigned
1: Signed
Relative to the maximum frequency:
0.00%~100.00%
Relative to maximum frequency:0.0%~
100.0%
- 79-
Default
Property
0
0
200.0%
0.100s
0.100s
0
100.0%
100.0%

Hide quick links: