Veikong VFD500 Series User Manual page 135

High performance vector and torque control frequency inverter
Hide thumbs Also See for VFD500 Series:
Table of Contents

Advertisement

VFD500 high performance vector control frequency inverter user manual Appendix A Modbus communication protocol
 Open collector type, push-pull output type encoder wiring:
Select the encoder power supply through SW3 on the PG card, SW1 and SW2 to the OC side, as
shown below::
Chart 7-5 Collector open type, push-pull output type encoder DIP switch selection
When wiring, the A-、B-、Z- terminals of the PG card are not wired, and the signal output of the
encoder is connected to the A+、B+、Z+ terminals of the PG card, as shown in the figure below.:
Chart 7-6 Collector open type, push-pull output type encoder wiring diagram
 Differential output encoder wiring:
Select the encoder power supply through SW3 on the PG card, SW1 and SW2 to the TP side,
as shown below:
7
8
9
13
14
15
16
17
18
12V
OC
OC
5V
TP
TP
MT500-PG-INC1
VCC
VCC
0V
A
PG
CARD
B
Z
SHIELDING
CABLE
- 133-
B+
Encoder B+signal
A-
Encoder A-signal
Encoder A signal
A+
Encoder W-
W-
signal
Encoder
W+
Signal
Encoder V-
V-
signal
Encoder
V+
Signal
Encoder U-
U-
signal
Encoder
U+
Signal
12V
OC
OC
5V
TP
TP
0V
A
ENCODER
B
Z
Note: UVW is
used to the
synchronous
motor
incremental
encoder, no
need wiring
when it is not
used.

Hide quick links: